74U vs 75U Injection Pens: What the Labels Mean, Why They Exist, and How to Choose

Summary: In pen-injector design, “U” almost always stands for units. A “74U” or “75U” pen refers to the maximum dose per injection that the dosing mechanism allows you to dial (e.g., up to 74 or 75 units). The one-unit difference comes from mechanical, regulatory, and human-factors choices made during device engineering—not from a change in cartridge size or drug concentration. This article explains the origin of these labels, how the mechanisms work, and what to consider when specifying 74U vs 75U in OEM/ODM projects.


1) What does “U” mean on an injection pen?

  • U = unit. In insulin systems, 1 unit (U) typically maps to 0.01 mL for U-100 insulin (100 units/mL).

  • In non-insulin biologics (e.g., GLP-1 class), dose is often labeled in mg; however, the pen’s mechanical index can still be designed around “unit-like” click steps that correlate to delivered volume. The display may show mg, IU, or a proprietary scale—while internally the pen advances metered volume per click.

Rule of thumb for U-100 insulin:

  • 75U max dose0.75 mL per injection (75 × 0.01 mL)

  • 74U max dose0.74 mL per injection

The cartridge capacity (e.g., 3.0 mL) is different from the per-injection maximum (e.g., 74U or 75U). The max dose is a mechanical stop, not the full cartridge.


2) Why do 74U and 75U both exist?

a) Tolerance & accuracy budgeting

Pen injectors must meet strict dose-accuracy requirements across temperature, aging, and manufacturing tolerances. Some engineering teams pick 74U as the hard stop to leave a small safety margin under 0.75 mL, especially when tolerance stack-ups could otherwise risk exceeding labeled volume. Others are comfortable certifying 75U given their tolerance analysis and test data.

b) Human-factors & labeling simplicity

  • 75 is a familiar round number that groups neatly with clinical titration patterns (e.g., multiples of 15).

  • 74 can be chosen to keep the usable volume strictly below three-quarters of a milliliter, which simplifies risk assessments in certain programs.

c) Portfolio harmonization

A company with multiple pens (e.g., half-unit pediatric, standard adult, concentrated insulin versions) may standardize max stops differently to keep dose windows, click counts, and training materials consistent across SKUs.

d) Regulatory strategy

During verification and clinical usability work, a sponsor may show that 74U yields better robustness for their specific drug viscosity, siliconization level, stopper friction, or cold-chain conditions—hence adopting 74U over 75U.


3) Inside the mechanism: how max dose is set

Pen injectors meter fluid with a screw/lead mechanism that advances a plunger rod a fixed distance per click. Three parameters set the per-click volume and maximum dose:

  1. Lead & pitch of the drive screw (how far the rod moves per click).

  2. Click geometry (ratchet details determine step size—e.g., 0.5U, 1U).

  3. Mechanical stop (prevents dialing beyond the validated maximum, e.g., 74U or 75U).

Designers then validate dose accuracy across:

  • Full temperature range

  • Viscosity/aging of the formulation

  • Cartridge glass tolerances & stopper friction

  • End-of-dose residuals (ensuring consistent delivery at near-empty)


4) Insulin vs GLP-1: how “U” maps to real dosing

  • Insulin (U-100): 1U = 0.01 mL. A 75U pen can deliver up to 0.75 mL in a single injection; a 74U pen, 0.74 mL.

  • GLP-1 pens (e.g., semaglutide): dose is commonly labeled in mg (e.g., 0.25 mg, 0.5 mg, 1.0 mg). The pen’s internal step may be engineered to mg, to mL, or to a unit-like scale that correlates to volume. In OEM, you can map clicks → mg to match your regimen and IFU.


5) 74U vs 75U: practical differences

Aspect74U Pen75U Pen
Max per-injection dose74 units (≈0.74 mL @ U-100)75 units (≈0.75 mL @ U-100)
Engineering rationaleExtra safety margin under 0.75 mLRound-number ceiling, convenient titration
Labeling & trainingMay emphasize conservative max volumeSimple, memorable upper limit
Accuracy/risk postureSlightly more conservative at the top stopSlightly larger max; still needs full V&V
Clinical impactTypically negligible (1U difference)Typically negligible (1U difference)

Bottom line: For most therapies and training programs, the 1-unit difference is not clinically meaningful. Choice should follow device verification data, human-factors testing, and labeling strategy.


6) OEM/ODM guidance: how to specify the right pen

When you brief a manufacturer, lock the following early:

  1. Drug & concentration

    • Insulin (U-100/U-200) vs non-insulin biologic (mg-based dosing).

    • Viscosity range & siliconization compatibility.

  2. Dose plan

    • Step size (e.g., 0.5U or 1U for insulin; mg steps for GLP-1).

    • Max per-injection dose (74U or 75U; or mg equivalent).

  3. Cartridge & interface

    • Glass cartridge nominal volume (e.g., 3.0 mL), stopper and crimp specs.

    • Needle interface and recommended lengths/gauges.

  4. Usability & IFU

    • Dose window readability, dial torque, end-of-dose cue (audible/visual).

    • Training graphics and multilingual labeling.

  5. Regulatory & test plans

    • Compliance to ISO 11608 series (needle-based injection systems).

    • Dose accuracy, free-flow, misuse scenarios, shipping & cold-chain robustness.


7) Example mapping (for planning)

  • Objective: 1U steps; max 75U; U-100 insulin

    • Per click = 0.01 mL; max dial = 0.75 mL

  • Variant: max 74U (conservative top stop)

    • Same step; max dial = 0.74 mL

  • GLP-1 variant: 0.05 mL per click; label in mg per IFU

    • Map click count to mg by assay; pick a top stop that matches titration schedule


8) FAQ

Q: Does 75U deliver more drug than 74U?
A: Only by 1 unit at the top of the scale (≈0.01 mL @ U-100). For most regimens, the clinical significance is minimal; follow your product’s IFU.

Q: Is 74U “safer” than 75U?
A: Neither is intrinsically safer. Safety depends on dose-accuracy validation, human-factors results, and training—not merely the number on the stop.

Q: Can we relabel 75U as mg for GLP-1?
A: Yes—labeling can show mg while the internal mechanism meters volume. You must validate the click-to-mg mapping.


9) How we support 74U / 75U programs (OEM/ODM)

At FillerInject, our engineering team customizes:

  • Dose step & top-stop (e.g., 74U vs 75U; mg mapping for GLP-1)

  • Drive train & torque for target viscosity and user force

  • Cartridge integration (3 mL common; others on request)

  • Branding (colorways, engraving, UI icons) and packaging (IFU, UDI)

  • Qualification & verification to ISO 11608 and your regional dossier plan

Next step: Share your dose plan (units or mg), concentration, and preferred top stop. We’ll return an engineering proposal with tolerance/accuracy budgets and a validation roadmap.


SEO extras for your page

  • Meta title: 74U vs 75U Injection Pens: Meaning, Origin, and OEM Design Guide

  • Meta description: Learn how 74U and 75U max doses are defined, why both exist, and how to specify the right pen in OEM/ODM programs for insulin or GLP-1.


Medical disclaimer: This article discusses device engineering and labeling. It is not medical advice. Dosing decisions must follow the drug’s prescribing information and your healthcare provider’s guidance.


With professional manufacturing, full OEM/ODM support, and fast global delivery — Sunrise Medical is ready to bring your brand to the next level.

Quick Links

Products

Contact Us

WhatsApp: +8615158132227
Phone: +86-15158132227
Email: andy@fyhealthcare.com
Address: Room 617, Building 2, Fuyi Garden Center, Shangcheng District, Hangzhou, Zhejiang, China
Copyright © 2025 Hangzhou Sunrise Medical Co., Ltd. All Rights Reserved. Sitemap | Privacy Policy